Lenses

Thermal, SWIR & UV lenses

How to choose a thermal, SWIR or UV lens

Germanium LWIR lenses for 8-14 um thermal cameras, SWIR lenses for 900-1700 nm InGaAs sensors, and UV lenses for 250-380 nm imaging. Check the detector format, pixel pitch and mount.

Thermal, SWIR & UV lenses

1-24 of 282 models

Products

Compare
LS-SWL-029275 mm UV lens, 200-1000 nm, 2/3", F3.8, F-mount 75 mm0.07X~0.5XF-mount2/3"F2.88 MP$1,540.00 Ships in 3-4 weeks
LS-SWL-029025 mm UV lens, 2/3", F2.8, C-mount 25 mm0.02X~0.2XC-mount2/3"F2.88 MP$2,860.00 Ships in 3-4 weeks
LS-SWL-029125 mm UV lens, 240-1000 nm, 2/3", F2.0, C-mount 25 mm-C-mount2/3"F2.08 MP$2,200.00 Ships in 3-4 weeks
LS-SWL-028935 mm UV lens, 240-380 nm, 1.2", F3.0, C-mount 35 mm-C-mount1.2"F3.0-$1,610.00 Ships in 3-4 weeks
LS-SWL-02812x UV lens, 190-700 nm -2.0xC-mount4/3"F13.8-$13,700.00Quote Ships in 3-4 weeks
LS-SWL-02770.5-1.0x UV lens, 190-700 nm, WD 180-94 mm, C-mount -0.5x-1.0xC-mount4/3"F6.9 / F10.4-$16,900.00Quote Ships in 3-4 weeks
LS-SWL-028314.8 mm UV lens, 254-380 nm, F1.4, M68 14.8 mm-M681.5"F1.4-$18,700.00Quote Ships in 3-4 weeks
LS-SWL-028878 mm UV lens, 200-1000 nm, 1", F3.8, C-mount 78 mm-C-mount1"F3.8-$2,365.00 Ships in 3-4 weeks
LS-SWL-02780.7x UV lens, 190-700 nm, C-mount -0.7xC-mount4/3"F8.3-$14,000.00Quote Ships in 3-4 weeks
LS-SWL-02801.4x UV lens, 190-700 nm, C-mount -1.4xC-mount4/3"F11.7-$13,700.00Quote Ships in 3-4 weeks
LS-SWL-0287100 mm UV lens, 240-280 nm, F2.5, M38 100 mm-M381.1"F2.5-$1,925.00 Ships in 3-4 weeks
LS-SWL-02760.5x UV lens, 190-700 nm, WD 222 mm, C-mount -0.5xC-mount4/3"F6.9-$14,000.00Quote Ships in 3-4 weeks
LS-SWL-028211.5 mm UV lens, 240-280 nm, F1.4, M36 11.5 mm-M361.1"F1.4-$3,740.00 Ships in 3-4 weeks
LS-SWL-028425 mm UV lens, 240-650 nm, F3.2, C-mount 25 mm-C-mount1.1"F3.2-$1,610.00 Ships in 3-4 weeks
LS-SWL-028550 mm UV lens, 230-400 nm, F2.8, M27 50 mm-M271.1"F2.8-$1,760.00 Ships in 3-4 weeks
LS-SWL-026625-1200 mm SWIR zoom lens, 400-1700 nm, 1/1.8", F4.8, C-mount 25 - 1200 mm-C-mount1/1.8"F4.8-10-$67,450.00Quote Ships in 3-4 weeks
LS-SWL-02791x UV lens, 190-700 nm, C-mount -1.0xC-mount4/3"F10.4-$13,300.00Quote Ships in 3-4 weeks
LS-SWL-028678 mm UV lens, 190-1000 nm, F3.8, F-mount 78 mm-F-mountAPS-HF3.8-$2,805.00 Ships in 3-4 weeks
LS-SWL-026420-360 mm SWIR zoom lens, 400-1700 nm, 1/1.8", F6, C-mount 20-360 mm-C-mount1/1.8"F6-10-$54,550.00Quote Ships in 3-4 weeks
LS-SWL-025815-360 mm SWIR zoom lens, 900-1700 nm, 1", F2.2, C-mount 15 - 360 mm-C-mount1"F2.2 to closed-$26,750.00Quote Ships in 3-4 weeks
LS-SWL-025435 mm SWIR lens, 900-1700 nm, 4/3", F1.4, C-mount 35 mm-C-mount4/3"F1.4-16-$850.00 Ships in 3-4 weeks
LS-SWL-026016-160 mm SWIR zoom lens, 900-1700 nm, 1", F2.2, C-mount 16-160 mm-C-mount1"F2.2 to closed-$15,000.00Quote Ships in 3-4 weeks
LS-SWL-02488.5 mm SWIR lens, 900-1700 nm, 2/3", F1.4, C-mount 8.5 mm-C-mount2/3"F1.460 lp/mm$400.00 Ships in 3-4 weeks
LS-SWL-025350 mm SWIR lens, 900-1700 nm, 2/3", F2.0, C-mount 50 mm-C-mount2/3"F2.030 lp/mm$400.00 Ships in 3-4 weeks

How to choose a thermal, SWIR or UV lens

Outside the visible band, ordinary optical glass stops working. It is opaque to long-wave infrared, absorbs deep ultraviolet, and its coatings and colour correction are designed for 400-700 nm. Thermal (LWIR), short-wave infrared (SWIR) and ultraviolet (UV) cameras therefore need lenses made from other materials and corrected for their own band. Start from the camera's waveband and detector, then choose focal length, aperture and the mechanical details.

1. Waveband: match lens, camera and light

BandLens wavelength rangeCamera / detector
LWIR (thermal)8-12 µmUncooled microbolometer, 12 or 17 µm pitch
SWIR900-1700 nm; VIS-SWIR lenses 400-1700 nmInGaAs sensor
UVFrom 190 nm; UV-C lenses 240-280 nm; others up to 700 or 1000 nmUV-sensitive sensor

Thermal lenses use infrared materials such as germanium and carry hard coatings on the front element. SWIR lenses are corrected and coated for the InGaAs band, so focus and contrast hold where a visible lens would lose both. UV lenses use UV-transmitting materials; choose the range that matches the light source, for example 254 nm or 365 nm.

2. Detector size and image circle

The image circle must cover the detector diagonal, which depends on pixel count and pitch:

Thermal detectorDiagonal
384 x 288, 12 µm5.8 mm
384 x 288, 17 µm8.2 mm
640 x 512, 12 µm9.8 mm
640 x 512, 17 µm13.9 mm

The thermal lenses here list the detector they were designed for, from 160 x 120 to 1024 x 768. SWIR and UV lenses are listed by sensor format (for example 2/3" or 1"), like visible lenses.

3. Focal length and spatial resolution

Thermal lenses here run from under 2 mm (very wide angle) to 180 mm fixed focal length, plus zoom lenses such as 30-150 mm and 36-180 mm for long-range monitoring. SWIR lenses include the usual machine vision steps from 12 to 50 mm. For thermal work, compute the pixel footprint: instantaneous field of view (IFOV) = pixel pitch / focal length. With a 12 µm detector and a 25 mm lens, IFOV is 0.48 mrad, so one pixel covers about 4.8 mm at 10 m. A hot spot needs several pixels across it for a reliable temperature reading, not just one. For field of view, the focal length calculator works for any sensor size.

4. Aperture

Microbolometers need a lot of radiation, so thermal lenses are fast: mostly F1.0-F1.2 here, with a few faster. A slower lens makes the image noisier, since thermal sensitivity worsens roughly with the square of the F-number. SWIR lenses here start at F0.9; UV lenses range from about F1.4 to F3.8.

5. Temperature, focus and sealing

The refractive index of germanium changes strongly with temperature, so a thermal lens drifts out of focus as it warms or cools. Athermalized lenses hold focus over their rated range, typically -40 to +80 °C for the lenses here; others are marked non-athermalized and suit stable indoor temperatures. Many are fixed-focus; others have manual or motorized focus. For outdoor or dirty locations, look for an IP67 front seal and a hard front coating (DLC). Check the mount: thermal lenses use threads such as M17 x 0.75, M20 x 0.5, M25 x 0.5, M34 or M45 x 1, or a flange, rather than C-mount.

Typical applications

  • LWIR: hot spots in electrical cabinets, heat seal and glue bead checks on packaging, process and kiln monitoring, fire and smoke detection.
  • SWIR: moisture and bruise detection in food, sorting plastics, looking through silicon wafers (silicon transmits above about 1.1 µm), laser spot checks at 1064 and 1550 nm.
  • UV: fluorescent adhesives, coatings and markings under 365 nm light; UV-C imaging at 240-280 nm, for example corona detection.

Common mistakes

  • Fitting a visible lens to a thermal camera: glass is opaque at 8-12 µm, so the image shows only the lens itself.
  • Putting a thermal camera behind a glass or acrylic window, which also blocks LWIR; use an infrared window.
  • Choosing a lens for a 12 µm detector on a 17 µm detector with the same pixel count: the image circle is too small.
  • Using a non-athermalized lens outdoors and refocusing every season.
  • Using a SWIR lens on a camera that only sees visible light, or a visible lens on an InGaAs camera, and losing contrast.

Questions

Can a thermal camera see through glass?
No. Window glass blocks long-wave infrared; the camera sees the glass surface temperature. Infrared windows (for example germanium) are used where a housing needs a window.

What does athermalized mean?
The lens design compensates for temperature so the focus stays put over the rated range, without refocusing.

Which cameras do these lenses fit?
The LWIR lenses fit the LWIR models among the infrared (thermal) cameras (MWIR cameras need MWIR optics). SWIR lenses fit InGaAs area and line scan cameras and 900-1700 nm hyperspectral cameras with the same mount. Check the mount and detector size on both product pages, or match them in the configurator.

How do I combine a thermal image with a normal camera image?
See thermal and RGB image fusion; it explains how to overlay the two without losing the temperature values.