Accueil / Case studies / Barcode contrast under coaxial line lights
Application study · Reflective identifiers and traceability

Reflective barcode imaging: compare four lights at a source-reported 35 µs

Four real captures show the same printed barcode/serial region under four coaxial line lights, each labelled 35 µs exposure. Their different brightness and bar contrast make a useful exposure-budget comparison without claiming a successful decode or transport speed.

Preserve the barcode structure before claiming a short-exposure reading result.

  • Source exposure35 µs on all four captures
  • Proposed acquired line2048 pixels
  • Proposed line field (derived)183.8 mm at the printed lens pair
  • Source acquisitionCamera/motion not identified
3D view of the inspection set-up: camera, lens, light and partDrag to rotate · scroll to zoom
3D illustration · real CAD where available
Walk through this setup 5 guided stops
From component to inspection

Understand each choice.

Choose a stop to frame the part in 3D and see why it belongs in this setup. The component notes and links remain available if 3D cannot load.

Camera and available lens CAD are published models. The light drawing gives the 340 × 56 × 115 mm body and 294 × 15 mm viewing port. The off-centre port, rotated housing and clear acquired line are shown; internal source and 45-degree optics are schematic. The acquired line is not a full area-camera frame. Part shape, unencoded 3D bars, transport, brackets and spacing are illustrative; no source conveyor or actual barcode payload is reproduced. Confirm optical/mechanical clearance, light drive and trigger timing. Light paths are not an optical simulation.

From the demo to your test bench

Build around the parts you can buy.

Explore each component, check its specifications and compare alternatives. The proposed quote includes the linked test station; its catalog listing includes two lighting holders.

Mount the optics with intent

The station is an optical test bench, with its two lighting holders included in the catalog listing. The 3D column and base follow the published height and footprint. Carriages, clamps and part supports are schematic: confirm camera screw pattern, lens support, light fasteners, permissible load and actual travel before ordering.

Configure the mounting station →

Complete the electrical system

Select a controller against the exact light voltage, drive mode and power, then confirm camera data/power/I/O cables and a suitable PC. These are not silently added to the proposed optical kit.

Lighting application-lab image sheet

Evidence you can inspect

Visible in the images

The four captures have different background brightness and barcode/serial contrast at the labelled 35 µs exposure.

What the source reports

The source states 35 µs for all four named lights but gives no source camera, transport speed, line rate or decoder result.

How to use this evidence

An application-lab lighting demonstration, not a customer deployment or a qualified production inspection. Proposed camera, lens, fixture and scene spacing require a fresh trial. Source observations do not establish a defect-size limit, accuracy guarantee or production false-call rate.

What the camera saw

Cropped from the source test sheet; original test annotations are retained. Captures are not generated or enhanced. Drag the comparison slider or use the image buttons.

Source 4COXL300 white capture, labelled 35 µs exposure.
Source 4COXL300 white capture, labelled 35 µs exposure.
Source 4COHL300 white capture, labelled 35 µs exposure.
Source 4COHL300 white capture, labelled 35 µs exposure.
Source 3COHL300 white capture, labelled 35 µs exposure.
Source 3COHL300 white capture, labelled 35 µs exposure.
Source 4COSL300 white capture, labelled 35 µs exposure; the print has a different visible contrast.
Source 4COSL300 white capture, labelled 35 µs exposure; the print has a different visible contrast.

The challenge

A reflective surface can lose the narrow bars in a weak signal or a bright background. A reliable reader needs preserved modules, margins and contrast at the required exposure.

How it was solved

The source names white LS-4COXL300, LS-4COHL300, LS-3COHL300 and LS-4COSL300. Each frame explicitly states 35 µs; its source camera and acquisition mode are not identified.

The proposed system uses a 2048-pixel line-scan camera and a matched M42 lens. It is a new moving-material concept, not evidence that the original test used line-scan acquisition. The illustrative transport is external to the quoted optical kit.

Why it works

  1. 1

    Coaxial line illumination aligns a concentrated bright field with a narrow inspection region. Enough light can support short exposure, but excessive brightness can also weaken the visible print contrast.

  2. 2

    Exposure time alone does not establish a line rate, conveyor speed or decoding performance. The proposed line rate must be calculated from the required field, sampling and motion, then verified on real codes.

From image contrast to a production decision

What to validate on your part

A useful sample image is the starting point. These are the checks that turn the concept into a defensible inspection.

  1. 01

    Check real code quality

    Include the required symbology, module width, quiet zones and acceptable print variation.

  2. 02

    Budget motion and line rate

    Calculate sampling, encoder triggering and permitted pixel travel using the actual transport speed.

  3. 03

    Validate decoding

    Test correct reads, no-reads and substitutions over representative reflective finishes at the chosen light and exposure settings.

Engineer the motion requirement

What line rate does your application need?

A planning calculation for the proposed 2048-pixel camera. Change the inspected width and transport speed to see square-pixel sampling. These are calculated requirements, not measured test results.

Across-web sampling
Required line rate
Exposure for 1 px travel

Sampling = width / 2048; line rate = speed / sampling.

The exposure value allows one pixel of motion blur; a stricter blur budget needs a shorter exposure. Verify light output, defect contrast, encoder timing, camera limits and network/PC capacity. Changing width requires revisiting lens magnification and working distance.

The set-up and the parts

Source exposure35 µs, as printed on each source capture
Source camera/acquisitionNot identified; no source line rate or speed given
Proposed cameraMV-CL024-91GM · 2048-pixel line scan
Proposed lens/fieldLS-AF2524M-M42 · printed 0.078x at 300 mm WD; derived 183.8 mm line field
Mounting (proposed)LS-BT-XZ-G-6-6045 · test station; external transport must be specified

"Tested" identifies the part named in the source. "Our pick" is a proposed alternative or supporting part. The quote includes only cards marked "In proposed setup", with the quantities shown; other test arrangements are separate. Confirm colour, optics, controllers, power supplies, cables and mounting before ordering.

About this case study: the photos and camera images come from the application laboratory of the maker of the lighting and optics we sell, imaged on the parts shown; your results depend on your part, camera and set-up. This is an application-lab study, not a LumaSpec customer deployment. Source figures are reported results; proposed components require a fresh trial. The 3D scene illustrates the arrangement and does not simulate imaging performance.

More case studies

Start with your inspection requirement

Make the next trial specific.

Tell us the part size, smallest defect or tolerance, available working distance, material and line speed. Include what a good part and a reject look like.