Ceramic-tile patterns: spread the light before judging the surface

A ceramic tile can look uneven because the lighting is uneven. These real captures compare a straight bar with an arc bar: the broader illumination makes the decorative pattern easier to inspect across the image.

Prove lighting uniformity before classifying a decorative pattern.

3D illustration of the inspection setup: Ceramic-tile pattern visibilityWhite arc bar: the pattern remains more visible across the captured field.Real camera capture
3D illustration of the arrangement
  • Proposed light housing (spec)196 × 20.3 × 27 mm
  • EvidenceReal lighting-lab captures
  • Camera (proposed)2448 × 2048 monochrome
  • Field (derived proposal)84.46 × 70.66 mm

Explore it in 3D

Ceramic-tile pattern visibility

Camera and available lens CAD are published models. Lens and light envelopes use printed dimensions. The linked station uses its published base size and column height; carriage, brackets, fittings, parts and spacing are illustrative. Confirm load, travel, fasteners and clearances before ordering. Light paths explain the arrangement and do not simulate optical performance. The part geometry is illustrative and is not reconstructed from the camera image. The proposed field is derived from the printed lens magnification and camera pixel dimensions; actual coverage and focus need a bench check. Representative part geometry is illustrative, not reconstructed inspection evidence.

The challenge

Natural-looking veins and a reflective glaze make it easy to confuse a brightness gradient with a surface change. A small bright patch can leave useful edges dark.

How it was solved

The sheet compares white LS-BAR-0664 and white LS-BAR-1069. The latter capture shows a more even bright field across the patterned surface.

The proposed rig uses one arc bar, a monochrome camera and macro lens on the catalog test station. Part size, light angle and working distance in the scene are illustrative.

Why it works

  1. 1

    Illumination spread controls which regions remain usable under one exposure.

  2. 2

    The printed sheet describes a larger, more uniform spot with the arc bar. Neither image is a labelled crack dataset: the visible veins must not be reported as damage.

Lighting application-lab image sheet

Evidence you can inspect

Visible in the images

The arc-bar capture shows the veined surface with a more even brightness distribution.

What the source reports

The sheet describes a larger and more uniform spot; no quantitative uniformity or defect-size result is supplied.

How to use this evidence

A lighting application-lab demonstration. The source supplies no customer deployment, defect-size limit, repeatability study or production false-call data. Proposed camera, lens, field, mounting and spacing are not the original tested system.

From image contrast to a production decision

What to validate on your part

  1. 01

    Map the field

    Capture a neutral target and the actual glaze at the centre and corners without auto exposure.

  2. 02

    Separate pattern and damage

    Include acceptable decorative veins and confirmed scratches or chips before defining rejection rules.

  3. 03

    Vary the finish

    Repeat with glossy and matt batches and the expected part height and tilt variation.

From the demo to your test bench

Parts in this setup

Build this system

"Tested" identifies the part named in the source. "Our pick" is a proposed alternative or supporting part. Confirm colour, optics, controllers, power supplies, cables and mounting before ordering.

The set-up

Lighting evidenceApplication-lab source captures
Camera and lensProposed catalog components; source camera unspecified
Proposed field (derived)84.46 × 70.66 mm at 0.1x
Lens working distance (spec)152 mm at the listed magnification
Mounting (proposed)LS-MNT-0097 · 600 mm station, glass tray and two lighting holders

Mount the optics with intent

The station is an optical test bench, with its two lighting holders included in the catalog listing. The 3D column and base follow the published height and footprint. Carriages, clamps and part supports are schematic: confirm camera screw pattern, lens support, light fasteners, permissible load and actual travel before ordering.

Complete the electrical system

Select a controller against the exact light voltage, drive mode and power, then confirm camera data/power/I/O cables and a suitable PC. These are not silently added to the proposed optical kit.

Build this system

Start from this setup, adapt it to your part.

The configurator opens with this study's camera, lens, light and station picked. Swap any part, check fit and price, then buy or ask for a quote.

Camera and available lens CAD are published models. Lens and light envelopes use printed dimensions. The linked station uses its published base size and column height; carriage, brackets, fittings, parts and spacing are illustrative. Confirm load, travel, fasteners and clearances before ordering. Light paths explain the arrangement and do not simulate optical performance. The part geometry is illustrative and is not reconstructed from the camera image. The proposed field is derived from the printed lens magnification and camera pixel dimensions; actual coverage and focus need a bench check. Representative part geometry is illustrative, not reconstructed inspection evidence.