1 dagars leverans på lagervarorMinst 3 års garantiKostnadsfri expertsupport från auktoriserade ingenjörerVolymrabatterNet 30 för företag
KonfigureraKonfigurera ett system
SV
EnglishFrançaisEspañolDeutschItalianoPortuguêsNederlandsSvenska日本語한국어简体中文
Offert
Hem / Case studies / Round-part diameter silhouette
Application study · Precision parts and gauging

Round components: a directional bright field makes the outside edge clear

A directional collector light produces a clean circular silhouette in the real source capture. The sheet reports0.005 mm measuring accuracy, but does not supply the calibration, source camera or repeatability needed to transfer that number to another system.

A reported accuracy needs a reproducible measurement method.

  • Proposed light housing (spec)Ø42 × 105 mm
  • EvidenceReal application-lab captures
  • Camera (proposed)2448 × 2048 monochrome
  • Field (derived proposal)33.78 × 28.26 mm derived from printed 0.25x magnification
3D view of the inspection set-up: camera, lens, light and partDrag to rotate · scroll to zoom
3D illustration · real CAD where available
Walk through this setup 5 guided stops
From component to inspection

Understand each choice.

Choose a stop to frame the part in 3D and see why it belongs in this setup. The component notes and links remain available if 3D cannot load.

Camera and available lens CAD are published models. Light envelopes and the station base/height use printed dimensions. Part shapes, brackets, holders, shielding and spacing are illustrative; they are not reconstructions of a source part or a complete mechanically validated assembly. Light paths explain the proposed arrangement and do not simulate optical performance. The proposed field is derived from the printed camera pixel dimensions and the stated lens magnification/working-distance pair, not measured from the source capture.

From the demo to your test bench

Build around the parts you can buy.

Explore each component, check its specifications and compare alternatives. The proposed quote includes the linked test station; its catalog listing includes two lighting holders.

Mount the optics with intent

The station is an optical test bench, with its two lighting holders included in the catalog listing. The 3D column and base follow the published height and footprint. Carriages, clamps and part supports are schematic: confirm camera screw pattern, lens support, light fasteners, permissible load and actual travel before ordering.

Configure the mounting station →

Complete the electrical system

Select a controller against the exact light voltage, drive mode and power, then confirm camera data/power/I/O cables and a suitable PC. These are not silently added to the proposed optical kit.

Lighting application-lab image sheet

Evidence you can inspect

Visible in the images

A clear dark circular outline and small bright central feature are visible in the source capture.

What the source reports

The original sheet reports measuring accuracy0.005 mm. It gives no source-camera pixel count, scale, uncertainty budget or repeated-trial method.

How to use this evidence

An application-lab lighting demonstration, not a customer deployment or a qualified production inspection. Proposed camera, lens, fixture and scene spacing require a fresh trial. Source observations do not establish a defect-size limit, accuracy guarantee or production false-call rate.

What the camera saw

Cropped from the source test sheet; original test annotations are retained. Captures are not generated or enhanced. Drag the comparison slider or use the image buttons.

Round component shown in the source sheet; its material and function are not identified.
Round component shown in the source sheet; its material and function are not identified.
Real source capture: a dark circular outline with a small bright central feature.
Real source capture: a dark circular outline with a small bright central feature.

The challenge

Diameter gauging needs an outside edge that remains stable under focus, height and illumination changes. A sharp-looking outline does not by itself establish the accuracy of an edge measurement.

How it was solved

The exact source light is white LS-2HSL10542. Its printed body is105 mm long and42 mm in diameter with a30 mm spot. The printed supply is3 V, so it must not be treated as a generic24 V light.

The camera and macro lens are proposed. The source-reported0.005 mm is not an accuracy claim for this proposed camera/lens/fixture.

Why it works

  1. 1

    A directional transmitted field can reduce stray-light wraparound at the outline and support a stable edge trial.

  2. 2

    A conventional macro lens still changes image scale with object distance. Telecentric optics may be needed if the required height tolerance makes that change unacceptable.

From image contrast to a production decision

What to validate on your part

A useful sample image is the starting point. These are the checks that turn the concept into a defensible inspection.

  1. 01

    Calibrate at the actual plane

    Use a traceable round artefact and the final focus/aperture; do not substitute pixel pitch for accuracy.

  2. 02

    Repeat loading and height

    Measure variation across reloads, rotations and the allowed object-height range.

  3. 03

    Build the uncertainty budget

    Include calibration, edge extraction, pose, optical distortion and thermal effects before setting a tolerance.

Explore your inspection requirements

How many pixels cover your feature?

Compare feature coverage, camera pixel requirements and exposure using your own planning inputs. These are calculated planning values, not inspection results or an accuracy specification.

Editable planning scenario. Adjust these example inputs for your application; they are separate from the source test and 3D setup. Motion allowance and target coverage are starting points to validate, not acceptance limits. Pixel count starts from the proposed camera's catalog resolution.

Object sampling0.04085 mm/px
Pixels across feature12.24 px
Horizontal pixels for target1000 px
Motion during exposure0.2448 px
Exposure ceiling from motion204.2 µs
Formulas and assumptions

The field, feature, speed and exposure start with neutral example values. They are not taken from the source test or the 3D illustration. Allowed motion starts at an editable 0.5-pixel example; it is not a recommended acceptance limit. Target coverage starts at an editable 5-pixel example; it is not a recommended detection or measurement threshold. The horizontal pixel count starts from the catalog Resolution row for MV-CS050-10GM(NPOE). Use the effective width after cropping, binning or decimation if those modes are enabled.

  • Object sampling (mm/px) = field width (mm) / horizontal pixels.
  • Pixels across feature = feature width (mm) / object sampling (mm/px).
  • Horizontal pixels for target = field width (mm) × target pixels across feature / feature width (mm), rounded up to a whole pixel.
  • Motion (px) = speed (mm/s) × exposure (µs) / 1,000,000 / object sampling (mm/px).
  • Exposure for allowed motion (µs) = allowed motion (px) × object sampling (mm/px) / speed (mm/s) × 1,000,000.

The exposure result is the maximum duration from this motion allowance alone. At zero speed, motion sets no exposure limit; the camera, lighting, saturation and other constraints still apply. A shorter exposure does not itself guarantee a reliable inspection.

Field width and feature width refer to the same object plane. The motion calculation assumes uniform linear motion parallel to the field-width direction and a single exposure. It does not model perspective, vibration, rolling-shutter distortion, diffraction, defocus or optical distortion. A strobe may change the effective exposure.

The target result is a horizontal sampling requirement, not a camera recommendation or a change to the selected camera. It uses the effective image width after cropping, binning or decimation and does not determine the vertical resolution or sensor size. Pixel coverage alone does not establish detectability or measurement accuracy. Validate contrast, lens performance, working distance, illumination, calibration, camera exposure limits and the inspection algorithm on representative parts. Changing field width does not change the 3D model or certify that the proposed lens can achieve that field.

The set-up and the parts

Source cameraNot identified in the source sheet
Camera and lensProposed catalog components
Proposed field33.78 × 28.26 mm derived from printed 0.25x magnification
Lens-to-part in proposed scene150 mm; printed working-distance pair
Mounting (proposed)LS-BT-XZ-G-6-6045 · catalog test station with two lighting holders

"Tested" identifies the part named in the source. "Our pick" is a proposed alternative or supporting part. The quote includes only cards marked "In proposed setup", with the quantities shown; other test arrangements are separate. Confirm colour, optics, controllers, power supplies, cables and mounting before ordering.

About this case study: the photos and camera images come from the application laboratory of the maker of the lighting and optics we sell, imaged on the parts shown; your results depend on your part, camera and set-up. This is an application-lab study, not a LumaSpec customer deployment. Source figures are reported results; proposed components require a fresh trial. The 3D scene illustrates the arrangement and does not simulate imaging performance.

More case studies

Start with your inspection requirement

Make the next trial specific.

Tell us the part size, smallest defect or tolerance, available working distance, material and line speed. Include what a good part and a reject look like.